PROFESSIONAL FIRE SYSTEMS:
If a fire alarm is initiated at your home or business, we'll know exactly where the alarm originated. And we'll know what kind of event has occurred. That precision can save precious time when fire fighters arrive.
Beyond high-quality hardware, we offer a complete package of key services
Fire Engineering
System Design
Code Compliance
Documentation
Proper Coverage
Certification
Annual Inspections
UL Protective Signaling Central Station Monitoring
UL Central Station Certificated Service

 

PANELS  
 Silent Knight 5820XL, Bosch D9124 , D7024 ,SENSORS & SOUNDERS  

The Silent Knight 5820XL, has modular design features and an easy-to-use interface that simplifies installation procedures. Plus, this incredibly smart system can differentiate between smoke and dust particles. With IntelliKnight, you'll be notified if you need the fire department or just a maintenance crew. And you'll know exactly where to find the problem.

The lntelliknight system uses data from the sensors installed on the signaling line circuits (SLC) to set sensitivity levels for each of the zones in the system. In addition, the Model 5820XL uses the data to perform drift compensation and sensitivity checks on each of the sensors in the system.

The IntelliKnight Model 5820XL can be expanded by adding modules such as the Model 5860 Remote Annunciator, Model 5815XL Signaling Line Circuit (SLC) Expander, Model 5824 Printer Interface (for printing system reports), and the 5895XL Intelligent Power Module. The Model 5820 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location.

 
  • Up to 508 addressable points.  
  • Supports Class A configuration for SLC (Style 6), SBUS, and Flexput circuits.
  • Distributed, intelligent power.
  • Drift compensation.
  • Flexput I/O circuits.
  • ANSI cadence pattern.
  • Built-in annunciator with 80-character LCD display.
  • RS-485 bus provides communication to system accessories.
  • Built-in RS-232 interface for programming via PC.
  • Built-in digital communicator.
  • Central station reporting by Point or by Zone.  
  • Form C trouble relay rated at 2.5 amps at 24 VDC.
  • Two Form C programmable relays rated at 2.5 amps at 24VDC.
  • Uses standard wire - no shielded or twisted pair required.
 

The Bosch D9124 Addressable Fire Alarm Control/Communicator provides detailed point identification through integrated addressable devices. Accurate information from individual points is communicated to the Central Station Monitoring facility.

[D9124 Fire Control Panel]

The detailed reporting capability of the D9124 provides a solution to system service and maintenance problems. The silencing of a "troubled" condition is a common occurrence with fire alarm systems. Using the D9124, your maintenance person won't be able to silence a "trouble" condition and forget about it. The location and time of the "trouble" will be reported to the central station and the required action can be taken. The base D9124 system configuration supports 127 points of detection or supervision. Optional accessory modules expand the system's capability, with up to 2,400 detection devices utilizing up to 246 individual reporting addresses.

 
The D7024  
Digital Fire Alarm Addressable Control/ Communicator Transmitter, expandable to 247 addresses with D7039
Supports conventional type detectors
Provided with 4 zones, expandable to 8
Two notification appliance circuits
Internal 24 volt, 4 amp power supply
Supports 4 remote Fire Command Centers
Built-in front panel display with controls
On-board programming capabilities
Remote programmable over dial up phone line
Event Activity Logger
Specialized fire software features
UL listed

The Bosch D7024 is a Microprocessor-based Fire Alarm Addressable Control/Communicator Panel. This four zone, expandable to eight zones in conventional mode, panel supports up to 20 conventional detectors per zone for a total of 160 detectors. Two Notification Appliance Circuits provide up to 2.5 amps of 24 volt power to operate horns, strobes, bells and other notification Appliances. Additional system power can be added using the D7038 Addressable Notification Power Supply, and can be expanded to two hundred and forty seven zones in addressable mode. The system has restricted access function keys to allow silencing of alarm and trouble conditions, zone bypassing, detector resetting, testing and other fire functions.

 

SENSORS & SOUNDERS
Horizon Security Systems offers a wide range of 12 and 24 volt sensors, including: ionization, photo-electronic, addressable and analog addressable smoke detector heads and bases; heat detector heads and bases. Horizon Security also offers a full range of 12 and 24 volt sounders, including motor bells, horns, mini-horns and strobes. Check the  Bosch Security online catalog for details.

sensors.jpg (9592 bytes)
strobe

ALTERNATE PATH OF COMMUNICATIONS WITH OUR CENTRAL STATION

 


|Home| |Integrated Access Control| |Fire Protection| |Security Systems| |Telephone Systems|
|About Us| |Contact Us|

Copyright © 1999 Horizon Security Systems. All Rights Reserved.