|
| |
|

|
|

|
|
PROFESSIONAL
FIRE SYSTEMS: |
| If
a fire alarm is initiated at your home or business, we'll know exactly where
the alarm originated. And we'll know what kind of event has occurred. That
precision can save precious time when fire fighters arrive. |
|
|
|
Beyond high-quality
hardware, we offer a complete package of key services
 |
Fire Engineering |
 |
System Design |
 |
Code Compliance
|
 |
Documentation
|
 |
Proper
Coverage |
 |
Certification |
 |
Annual Inspections |
 |
UL Protective
Signaling Central Station Monitoring |
 |
UL Central Station
Certificated Service |
|
| PANELS |
|
|
Silent Knight
5820XL, Bosch FPA-1000, D9124
, D7024 ,SENSORS &
SOUNDERS |
|
|
 
 |
The Silent Knight 5820XL, has
modular design features and an easy-to-use interface that simplifies
installation procedures. Plus, this incredibly smart system can
differentiate between smoke and dust particles. With IntelliKnight, you'll
be notified if you need the fire department or just a maintenance crew. And
you'll know exactly where to find the problem.
The lntelliknight system uses
data from the sensors installed on the signaling line circuits (SLC) to set
sensitivity levels for each of the zones in the system. In addition, the
Model 5820XL uses the data to perform drift compensation and sensitivity
checks on each of the sensors in the system.
The IntelliKnight Model 5820XL
can be expanded by adding modules such as the Model 5860 Remote Annunciator,
Model 5815XL Signaling Line Circuit (SLC) Expander, Model 5824 Printer
Interface (for printing system reports), and the 5895XL Intelligent Power
Module. The Model 5820 also features a powerful built-in dual line fire
communicator that allows for reporting of all system activity to a remote
monitoring location.
The FPA‑1000‑UL Compact Fire
Panel is an advanced analog control panel for
small to medium facilities in commercial or public building applications.
The FPA‑1000‑UL combines complete built-in Fire Alarm Control Panel (FACP)
equipment such as Notification Appliance Circuits (NACs), Signaling Line
Circuits (SLCs), relays, power supply, Digital Alarm Communicator
Transmitter (DACT), and Ethernet.
- Includes one FPE‑1000‑SLC Signaling Line Circuit,
configurable as two Class B Style 4 or one Class A Style 6 or 7
- Expandable by adding a second FPE‑1000‑SLC Signaling
Line Circuit
- Up to 127 detectors and modules, plus 127 analog
sounder bases in combination with a suitable detector.
- Two integrated NAC circuits rated at 2.5 A each
(unsynchronized), allowing up to 4 A total current (including NAC, Option
Bus and Aux power)
|
|
|
|
The
Bosch
D9124 Addressable Fire Alarm Control/Communicator
provides detailed point identification through integrated addressable
devices. Accurate information from individual points is communicated
to the Central Station Monitoring facility.
|
![[D9124 Fire Control Panel]](site/Fire%20Protection_files/d9124fcp.gif) |
The detailed
reporting capability of the D9124 provides a solution to system service
and maintenance problems. The silencing of a "troubled" condition is
a common occurrence with fire alarm systems. Using the D9124, your maintenance
person won't be able to silence a "trouble" condition and forget about
it. The location and time of the "trouble" will be reported to the central
station and the required action can be taken. The base D9124 system
configuration supports 127 points of detection or supervision. Optional
accessory modules expand the system's capability, with up to 2,400 detection
devices utilizing up to 246 individual reporting addresses.
|
|
|
The FPD-7024 |
|
|
|
 |
Digital Fire Alarm
Addressable Control/
Communicator Transmitter, expandable to 247 addresses with D7039 |
 |
Supports conventional
type detectors |
 |
Provided with 4 zones,
expandable to 8 |
 |
Two notification appliance
circuits |
 |
Internal 24 volt, 4 amp
power supply |
 |
Supports 4 remote Fire
Command Centers |
 |
Built-in front panel display
with controls |
 |
On-board programming capabilities |
 |
Remote programmable over
dial up phone line |
 |
Event Activity Logger
|
 |
Specialized fire software
features |
 |
UL listed |
|
The FPD‑7024 Fire Alarm
Control Panels (FACPs) can be used in commercial and
public building applications such as schools, universities,
manufacturing plants, and health care facilities. They are listed by UL
for central station, local, auxiliary, and remote station systems. The
FPD‑7024 FACPs support four on‑board initiating zones that can be
expanded to eight using the FPC-7034. The Bosch
FPD-7024 is a
Microprocessor-based Fire Alarm Addressable Control/Communicator Panel. This four
zone, expandable to eight zones in conventional mode, panel supports up to 20 conventional
detectors per zone for a total of 160 detectors. Two Notification Appliance
Circuits provide up to 2.5 amps of 24 volt power to operate horns, strobes,
bells and other notification Appliances. Additional system power can
be added using the D7038 Addressable Notification Power Supply, and
can be expanded to two hundred and forty seven zones in addressable
mode. The
system has restricted access function keys to allow silencing of alarm
and trouble conditions, zone bypassing, detector resetting, testing
and other fire functions.
|
|
SENSORS
& SOUNDERS
Horizon Security Systems offers a wide range of 12 and 24 volt sensors, including:
ionization, photo-electronic, addressable and analog addressable smoke
detector heads and bases; heat detector heads and bases. Horizon
Security also
offers a full range of 12 and 24 volt sounders, including motor bells,
horns, mini-horns and strobes. Check the Bosch
Security
online catalog for details.
|


|
|
ALTERNATE PATH OF COMMUNICATIONS WITH OUR CENTRAL STATION

| KEY FEATURES ON THE 7845GSMR Digital Cellular
Communicator
This groundbreaking communications solution offers
full data reporting and uploading/downloading with the
industry fire alarm control panels.
- Universal Control Panel
Compatibility
- Dialer Capture Ready
- UL 864 - Control Units for Fire Protection
Signaling Systems
- UL 985 - Household Fire Warning System Units
- Housed in red metal cabinet with key lock
- Web - Based Programming
- Dual - Path Technology- Uses GPRS (General Packet
Radio Service) as primary digital cellular path and
automatically switches to SMS ( Short Message Service)
if GPRS is unavailable.
|
| |
|
|
|
|
|